RCQT Research Center for Quantum Technology · Chiang Mai University

Interactive lab › Lock a laser to an atom and to a cavity

Interactive lab · 4/66 · Laser locking · ECDL

Lock a laser to an atom and to a cavity

Every cold-atom experiment needs lasers that stay within a fraction of a megahertz of an atomic line. An external-cavity diode laser, like the Cateye laser RCQT patented, is tuned onto a feature of a rubidium vapour cell or an optical cavity, and a feedback loop holds it there. Choose the reference and the detection, then disturb the laser.

What you are seeing

  • Top: light through a rubidium cell. The broad dip is the Doppler-broadened absorption; the narrow peaks are the hyperfine lines and the crossovers half-way between them, revealed by a counter-propagating pump beam.
  • Bottom: the error signal. Modulating the laser frequency and demodulating at the first harmonic gives the derivative of the spectrum; at the third harmonic it gives the third derivative, which flattens the sloping Doppler background so the zero crossing sits on the line itself.
  • Pound–Drever–Hall uses phase-modulation sidebands and the light reflected from a high-finesse cavity: a far steeper slope, a capture range of ±Ω, and a loop that can be much faster.
  • Press “Kick it”: within the capture range the loop pulls the laser back; beyond it the laser runs to another zero crossing or away.

The numbers in the model

87Rb D2 hyperfine lines from F = 2F′ = 3 · 2 · 1 at 0 · −266.65 · −423.60 MHz
Doppler width at room temperature (σ)≈ 220 MHz
Cavity in the modelfree spectral range 1.5 GHz; linewidth = FSR / finesse
Loopintegrator; up to 700 Hz with a lock-in, 7 kHz with PDH
Dip heightstypical values, not calculated

Go further