About › RCQT × CEQT
RCQT × CEQT
One programme, two centres
Chiang Mai University's cold-atom trilogy is the written programme of its two quantum centres. It divides the subject along a single seam: RCQT owns the apparatus; CEQT owns what is computed and how it is controlled.
RCQT · Faculty of Science
The apparatus
- Vacuum, lasers and atom optics
- Traps, tweezers and detection
- Calibration and traceability
- Field campaigns with real instruments
CEQT · Faculty of Engineering
What is computed, and how it is controlled
The seam is the same in all three books. In Cooling and Trapping of Neutral Atoms it is “apparatus at RCQT, algorithms at CEQT”; in Cold-Atom Quantum Simulation RCQT builds the tweezer arrays and CEQT supplies the algorithms and the verification; in Atom-Based Quantum Sensing and Metrology it becomes a written contract.
The interface, written as deliverables
The trilogy's last chapter turns the division into a contract: for each CEQT pillar, what CEQT delivers, what RCQT does with it, and the number that decides whether it worked. It is written this way on purpose — an interface of deliverables with numerical acceptance criteria, not a collaboration agreement.
| CEQT pillar | CEQT delivers | RCQT | Accepted when | Chapters |
|---|---|---|---|---|
| Algorithm design | Optimised, robust pulse shapes and dynamical-decoupling sequences | Calibrates them on the apparatus | π-pulse efficiency ≥ 0.995 over ±10% intensity and ±2π × 20 kHz detuning, at 5σ | 31, 9 |
| Simulation | Ring potentials with roughness, condensate dynamics, wavefront propagation and Monte Carlo systematics — with the contrast and bias they predict | Measures blind | Agreement within 10% in contrast, and within the budget's uncertainty in bias; a gap over 2σ triggers a model review | 15, 16, 12, 33 |
| Software and platforms | Control architecture, data pipeline, digital twin, reproducibility | Hardware interface, timing layer, calibration | A run is reproduced from its versioned specification by a different operator, within the Type A uncertainty | 30 |
| Foundations | Estimation theory and bounds, adaptive and Bayesian estimators, verification | Tests them on real data and releases the raw data | The estimator holds on RCQT's measured data, published with it | 2, 34 |
Chapters of Atom-Based Quantum Sensing and Metrology; the contract is in Chapter 38.
Instrument by instrument
Who does what on each of the programme's machines.
They meet at the FPGA · Ch. 10–13
Fountain gravimeter
RCQT — the fountain, Raman lasers, vacuum and field campaigns.
CEQT — the error-budget audit tool (Ch. 33), the optimal-control toolbox (Ch. 31) and the timing layer.
Ch. 14–17
Ring-trapped navigator
RCQT — the condensate, ring loading, Bragg optics and the parity experiment; an inductively coupled ring for deployment and a holographic ring for the physics.
CEQT — timing and sequencing, shot-by-shot estimators, corrugation and hologram feedback, potential tomography, the reversal protocol and the Allan pipeline — then ruggedised electronics and vehicle integration.
They meet at the digitizer · Ch. 18–20, 24
SERF magnetometer
RCQT — sensor heads, lasers, the four-layer μ-metal shield and coils.
CEQT — maternal–fetal subtraction, source localisation (Ch. 34), crosstalk inversion, the real-time pipeline (Ch. 30) and uncertainty reporting (Ch. 35); its diamond-magnetometer bench shares RCQT's shield and coils and is cross-calibrated against the SERF sensor.
Each is the other's referee · CAQS Ch. 23, 26–30
Single-atom arrays
RCQT — the tweezer-array hardware, and the measured error of every coupling.
CEQT — algorithms and encodings, the optimisation programme — max-cut, portfolio optimisation, vehicle routing and cybersecurity formulations, benchmarked against the best classical solver — and the verification protocol.
Working rules
Simulations are written down before the measurement, and the measurement is taken blind.
A new estimator counts once it works on real data, and the raw data are published with it.
Hardware and algorithms fail in different ways, so each half checks the other's claims.
Halving a sorting round is worth as much as doubling the vacuum lifetime — software and hardware gains are traded on one scale.
A staged plan
The programme moves in phases, each closed by a go/no-go test. Phase 0, to 2027, ends with a first signal and a measured noise floor. It passes if the single-shot noise is within a factor of two of the noise budget computed in advance — a test that needs both centres.
One pipeline of people
One graduate programme at RCQT and CEQT supplies both the physics and the algorithms. Students enter through RCQT's degrees in Quantum Science and Technology or CEQT's degrees in quantum engineering:
Which centre do you need?
- Something measured to extraordinary precision — gravity, magnetic field, time, acceleration, rotation: RCQT. Start at the sensors.
- A quantum instrument, laser system or its electronics, designed or built: RCQT, with CEQT on the control and software side.
- An optimisation, simulation, modelling or algorithm problem: CEQT — Optimisation, Cybersecurity, Finance, Chemistry, Energy, Machine learning, Complex systems.
- A degree: Quantum Science and Technology at RCQT, or quantum engineering at CEQT — Education.
The same seam runs through RCQT's focus programme for 2023–2030: its three sensing projects and the Rydberg simulator rest on RCQT's apparatus, while its quantum-computing projects in cybersecurity, finance, materials and aerospace rest on the algorithms and software that are CEQT's specialty.
Neither site repeats the other. The apparatus, the simulator, the sensors and RCQT's computing projects are described here, the algorithms and software behind them on the CEQT site; where a theme spans both, each site carries its own half and points at the other. The two centres currently publish one combined list of publications.
Every CEQT page, from here
The sister site, ceqt.eng.cmu.ac.th.